Attachment E: Bar Code Verifiers - Reference
Printable PDF
Format
Recommended Capabilities:
-
Follow ANSI X.3182-1990 standard or ISO/IEC 15426-1 standard
-
Verify UCC/EAN 128 bar code
-
Verify bar codes which have a physical length of up
to 9.86 inches (250mm)
-
Verify bar codes which have a narrow bar width of
25-40 mils (0.6mm-1mm)
-
Verify using the ANSI grading scale
-
Provide an "A-F" grade for a verified bar code
-
Provide the parameter which is causing a low ANSI
grade
-
Use a light pen or mouse vs a non contact scanner
-
Have a laser aperture size of 20 mils (0.5mm)
Other Capabilities nice to have:
-
Battery and 120/240 volt line powered
-
LCD display giving ANSI grades on screen
-
Printer which gives ANSI grading information in
hardcopy
-
Printer which gives scan profile
-
RS-232 output for dumping data to a data file
-
Data base software for storing data
-
Data analysis program for troubleshooting the cause
of poor ANSI grade and suggesting printing changes
Back to the P&G Compliance Index Page
|
|
|
|
 |
|
 |